Akai Mpc 3000 – OS Version 3.50 Vailixi Firmware Chips Sampler Drummachine New

If you buy after clicking affiliate links on this site we might receive a commission from companies such as eBay, Amazon etc This does not affect the price you pay.
Akai Mpc 3000 - OS Version 3.50 Vailixi Firmware Chips Sampler Drummachine New

If you buy after clicking affiliate links on this site we might receive a commission from companies such as eBay, Amazon etc This does not affect the price you pay.
Click here to see similar items on eBay, and to buy.

Akai Mpc 3000 – OS Version 3.50 Vailixi Firmware Chips Sampler Drummachine New

 

The description of this item has been automatically translated. If you have any questions, please feel free to contact us.

Akai MPC 3000 OS 3.50 Vailixi Operating System Eprom UpgradeFirmware Vailixi 3.50 is a special OS developed by third-party and is a sought-after upgrade for any Akai MPC 3000 sampler user. This operation system update / upgrade requirestwoeprom chips as revealed in the ebay article`s photos and the chips wants to label the correct chip socket. For more info, please check below. COMPATIBLE WITH ALL AKAI MPC 3000 AND ALL OS VERSIONS! ADDS COMPATIBILITY WITH MANY CF CARD READERS READ AND WRITE AKAI PARTITIONS ON CF CARDS WITH YOUR COMPUTER EXCHANGE SAMPLES WITH YOUR COMPUTER (WINDOWS / MAC) Features/improvements: 1. Boot screen shows software revision. 2. System Information screen shows detailed info about memory availability and installed option function. 3. Program Load screen now features PGM, SND or SET files. 4. EDIT SND screen now features a TRUNC SFT + END function. This allows samples either side of the SOFT START and SOFT END points to bedeleted in a single button push. 5. EDIT SND screen features now a COPY ZONE -> SND function. Zones to be transformed directly intoa new sound in memory from a single button push. Define a ZONE start and end, COPY ZONE -> SND and a new SOUND will appear in memory.The new SOUND created via this process wants to be named “ZONE” with an incremental number appended for easy location within memory. 6. Samples can now be edited in real-time and / or while the sequencer is playing or recording. 7.The PROGRAM / SOUNDS screen now features a COMPRESSION option. 8. New timing correct / step size options: 1/128 and 1/192 timing correct OFF note value resolutions added.1/4, 1/4 TRPLT, 1/64, 1/64 TRPLT timing correct note value resolutions added.Swing is now available for 1/4, 1/4 TRPLT, 1/8, 1/8 TRPLT, 1/16, 1/16 TRPLT, 1/32, 1/32 TRPLT, 1/64, 1/64 TRPLT. 9. MIDI CLOCK can be sent to all 4 MIDI output ports simultaneously. 10. MIDI TIME CODE can be sent to all 4 MIDI output ports simultaneously. 11. Extra system parameter Menu.”SND playback stops on STOP” allows all samples to be stopped when the sequencer is stopped from any running state.Allows blocking of sequence change attempts while the sequencer is running in record or record ready mode.”Stay in EDIT SND on PLAY / PLAY START” allows the sample editor to open when PLAY / PLAY START is pressed.”Mute audio during EDIT SND processes” allow the audio to be muted when samples are being edited in real time with the sequencer running in PLAY or RECORD.PLAY / PLAY START allows all mixer screens to stay open when PLAY / PLAY START is pressed. 12. SCSI Disk now features a robust sector at a time disk copier. 13.Make SCSI Hard Disk Active Menu.Make SCSI Hard Disk Active has now released SCSI multi sector transfer mode.Make sure the device is enabled or disables SCSI bus reset messages between device selection attempts during the AUTO search for device phase. 14.Format Hard Disk now has “Software Low Level Format” option. 15. Format Hard Disk now has a “Low Level Software Format” failback mode.Option to now “hybrid partition” a SCSI hard disk. Hybrid partitions are safe cross platform types that can be accessed by computers and the MPC3000disk data for the purpose of rapid file transfer and sound library development. 16.Large samples up to 32Mb in size can now be saved to disk in a single file. This useful feature allows you to use your MPC3000 as a restingsr forperiods up to the length of it’s entire 32Mb sample RAM space. General Bugs Fixed The Vailixi 3.50 update not only adds to your MPC3000 but so there are some long time outstanding bugs which you may have encountered through your machine. Corrected a bug known to exist since 3.00 system when it was detected when accessing certain menu options and soft keys. The MPC3000 no longer displays these error messages. Menu options and soft keys are now in the correct manner. Corrected a bug known to exist since 3.00 where audio outputs would remain in an un-muted or active state when loading or saving sounds from and to disk.The MPC3000 audio outputs should now be a lot quieter when loading or saving sounds from and to disk. Corrected a bug introduced in system 3.12 where incorrect error messages would be displayed when attempting to load the maximum number of SND files into memory via a PGM.The MPC3000 now reports that there are too many sounds in memory rather than incorrectly stating that sequencer memory is running low. 3.00 where sound memory management would become extremely unstable when recording a sample over 327.6 163.8 (STEREO / MONO) seconds in length. 32 megabytes equipped machines can now use the full memory for sample recording purposes.3.00 that affected MIDI input processing and system stability when the SEQUENCER was in a STOPPED or IDLE state. CPU overload when the SEQUENCER was in a STOPPED or IDLE state. Intense and complex incoming MIDI message streams, particularly running status, multiple continuous controllers and heavy system exclusive dumps. MIDI events thru or recording into the SEQUENCER when started from a STOPPED or IDLE state. The SEQUENCER is STOPPED or IDLE and protects against CPU overload. Sequencer memory initialization at boot now updates default unused track flags to unused. MIDI data input processing speed increased. Re-write of SCSI protocol engine to fix compatibility with recalcitrant storage devices. Redundant functions removed NOTE: All EPROMs are properly packaged in anti-static material to ensure quality. You have to swap two epromsIC 13 (LS)andIC 14 (MS)[What is this?]Akai, synthesizer, upgrade, update, midi, firmware, eprom, sequencer, sampler, Mansell labs, workstation, groovebox, hiphop, 90s, rare, DIY, hardware, modification Marke Akai Herstellungsland und -region Deutschland EAN Nicht zutreffend Modifizierter Artikel Nein Modell MPC 3000 Herstellernummer nicht zutreffend Auslndisches Produkt Nein Angebotspaket Nein Produktart Groovebox

If you buy after clicking affiliate links on this site we might receive a commission from companies such as eBay, Amazon etc This does not affect the price you pay.
Click here to buy, and to see similar items on eBay

 

 


Category: Musical Instruments:Pro Audio Equipment:Samplers and Sequencers
Location: Offenbach, Hessen